Specification
* Mfr Part Number: SMART3000RM2U * Voltage compatibility: 120 V AC * Frequency compatibility: 60 Hz * Output: o Output volt amp capacity: 3000 VA o Output watt capacity: 2250 watts o Output nominal voltage: 120 V AC o Output voltage regulation: Line mode - Sine wave line voltage 120V (-18% / +8%); Battery mode - Sine wave output 120V +/-5% o Output frequency regulation: Line mode - Passes line frequency of 60Hz +/-10%; Battery mode - Inverter output regulated to 60Hz +/-0.5Hz o Outlet quantity / type: 4x NEMA 5-15R; 4x NEMA 5-20R; 1x NEMA L5-30R o Overload protection: Resettable circuit breaker * Input: o Maximum input amps: 24 A o Input connection type: NEMA L5-30P o Input cord length: 10 ft., 10 gauge o Recommended electrical service: 30A 120V * Battery: o Full load runtime: 4 minutes (3000 VA) o Half load runtime: 13 minutes (1500VA) o Expandable battery runtime: Supports extended runtime with optional external battery packs BP48V242U (limit 1) and BP48V60RT3U (multi-pack compatible) o DC system voltage: 48 V DC o Typical battery lifespan: 3~6 years, depending on usage o Battery recharge rate: 2~4 hours to 90% * Voltage Regulation: o Overvoltage correction: Input voltages between 128 and 147V AC are reduced by 12% o Direct pass through: Input voltages between 105 and 127V AC are passed on to connected equipment unchanged o Brownout correction: Input voltages between 95 and 104V AC are boosted by 12% o Severe brownout correction: Input voltages between 79 and 94V AC are boosted by 24% * Surge / Noise Suppression: o AC surge suppression: 480 joules o AC suppression response time: Instantaneous o EMI / RFI AC noise suppression: Yes * Communications: o Network monitoring port: 4x built-in monitoring ports, 2x USB, 2x DB9 o SNMP compatibility: Built-in accessory slot accommodates internal SNMP / Web card and other network accessories o WatchDog compatibility: Yes * Line / Battery Transfer: o Transfer time from line power to battery mode: 2~4 milliseconds o Low voltage transfer to battery power: 79V (resets to line power as voltage increases to 83V) o High voltage transfer to battery power: 147V (resets to line power as voltage decreases to 144V) * Certifications: UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico) * Special Features: o EPO port: Includes RJ11 EPO (emergency power off) port and interconnection cable o TVSS grounding: Includes back panel grounding point with thumbscrew for data line surge suppressors and other network accessories requiring a safe grounding point o Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure o Appearance: Attractive gray rackmount housing, optional use 2U black front bezel included to enable black color appearance * Physical: o Material of construction: Steel o Form factors supported: Rack/Tower (2U) o Cooling method: Built-in cooling fan o Battery Access: Battery access door allows hot swap battery replacement without powering connected equipment off o Dimensions (WxDxH): 17.5 x 19 x 3.5 inch / 44.5 x 48.3 x 8.89 cm o Weight: 64 lbs / 29.1 kg
|